Shutter and Shopfront.uk 0800 088 6248 Get a price
  1. Home
  2. Guides
  3. How often should a roller shutter be serviced?

How often should a roller shutter be serviced?

There is no blanket UK law that says how often a roller shutter must be serviced. The right schedule comes from the manufacturer's instructions, how often the shutter opens and the condition it is in. Twice a year is a common commercial recommendation for frequently used shutters, but it is a recommendation, not a legal interval.

By the Shutter and Shopfront UK team

Is there a legal service interval for a roller shutter?

No, there is no blanket legal rule that every shutter must be serviced every 6 or 12 months. If a website says the law sets 6 months, it is wrong. What the law asks for is upkeep. In a workplace, the equipment and devices the regulations cover must be maintained in an efficient state, in efficient working order and in good repair. Where appropriate, they must also be under a suitable system of maintenance.

Where Workplace rule If the shutter is work equipment
England, Wales and Scotland Workplace (Health, Safety and Welfare) Regulations 1992, regulation 5 Provision and Use of Work Equipment Regulations 1998 (PUWER), regulation 5
Northern Ireland Workplace (Health, Safety and Welfare) Regulations (Northern Ireland) 1993, regulation 5 Provision and Use of Work Equipment Regulations (Northern Ireland) 1999, regulation 5

HSE's Approved Code of Practice for the 1992 regulations names powered doors as an example of equipment that needs a system of maintenance. It says the frequency "will depend on the equipment or device concerned" and points to manufacturers' information and instructions. HSE also says user instructions should cover routine maintenance and how often safety checks are needed, so find those first.

Manual shutters are not outside this. Regulation 18 requires a device to stop an upward-opening door falling back, and that device has to keep working. HSENI, the Northern Ireland regulator, has told duty holders with powered gates to have a planned preventative maintenance system.

This is general information, not legal advice. Check your own duties with your health and safety adviser.

How do I set a service schedule from use?

Start with the manufacturer's instructions, then adjust for cycles and condition. One cycle is one open and one close, and wear follows cycles, not the calendar. Use the opens-per-day check to get a figure for your shutter, then agree a risk-based schedule with whoever services it.

How the shutter is used Sensible starting point
Manual shutter, opened morning and night Follow the instructions and review condition at each visit
Electric shutter opened every trading day Twice a year is a common recommendation for frequent use
Busy goods-in door Set it from the cycle count and what each visit finds. It may need more than twice a year
Any shutter that relies on force limitation Include force testing in planned maintenance
Any shutter that has been hit, adjusted or repaired Have it checked before it goes back into normal use

Review the schedule when use changes. If a visit finds fast wear, shorten the gap. If a potentially dangerous defect turns up, HSE's Code says it should be put right immediately or the people at risk protected, so do not wait for the next service.

What should a shutter service include?

A service should check the parts that commonly wear and the safety devices that protect people. A service and safety check is £174 per shutter inc VAT, with parts extra.

The parts that commonly wear or fail are the counterbalance springs, motor and limits, laths, guides, bottom rail, controls and photocells. Wound springs store a lot of energy, so spring work is for engineers only. Never adjust springs, limits or the bottom bar yourself.

Where force limitation protects people, DHF TS 013-1:2025 calls for force testing at commissioning, after adjustments that could change force, and during planned maintenance. The instrument should be calibrated annually. Ask to see the result. It belongs in your records.

What service records should I keep?

Keep a dated record of every service, test, repair and defect. Regulation 5 does not set a format, but records show what was done and when. PUWER says that where machinery has a maintenance log, the log must be kept up to date. HSE says records of force testing should be kept.

  • The instructions and, for a powered shutter, the Declaration of Conformity
  • Dated service sheets showing who attended, what they found and what they changed
  • Force test results and the calibration date of the instrument
  • Repairs, parts fitted and any adjustments
  • Faults reported by staff, and when each was closed
  • Your opens-per-day figure, so the schedule can be reviewed

To book a service and safety check, go to the shutter servicing page.

Quick answers

Does the law say a roller shutter must be serviced every 6 months?

No. There is no blanket legal interval. Follow the manufacturer's instructions and set a schedule from use and condition.

Do manual roller shutters need servicing?

Yes, they need upkeep too. Springs, laths and guides wear with use, and an upward-opening door must have a device that stops it falling back.

How much does a roller shutter service cost?

A service and safety check is £174 per shutter inc VAT, with parts extra. Spring and curtain work is quoted after inspection.

Are the rules the same in Northern Ireland?

The duties are similar, but the law is separate. Northern Ireland uses its own 1993 workplace regulations and its own 1999 work equipment regulations, not the Great Britain versions.

Have an opening to price?

Answer four quick questions and see a guide price straight away.

WhatsApp